Testing device UL 94 / DIN EN 60695-11-2 / -11-3 / - 11-4

Characteristics

  • Tests determining the fire hazard.

The testing device consists of a multi-axle electronic control of the burner position and a multi-function timer for recording different stages of the process. It also includes a partly automatic calibration mechanism for adjusting the flame heating value. According to the standard tests using the 50 W testing flame, the 500 W testing flame or the 1 kW testing flame can be used. For security purposes the burner is equipped with an electronic pilot flame safety which is provided by a thermocouple. The power supply for the controller is provided by an IEC-320 AC power cordset 230 VAC (50/60 Hz).

Technical specifications

Geometry of specimen:Textiles / synthetic materials
Testing standards:UL94 DIN EN 60695-11-2 - 11-3 - 11-4
Sensory functions:Temperature / time
Power input:230 VAC / 500 VA
Methane gas / compressed air (DIN EN 60695-11-2)
Dimensions (testing device):1500 x 800 x 1800 mm (W x D x H)
Weight (testing device):ca. 200 kg